beautypg.com

NORD Drivesystems BU0180 User Manual

Page 131

background image

6 Parameterisation

BU 0180 GB-0914

Pre-series version

131

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P727

Mechanical power

(Mechanical power)

-99.99 ... 99.99 kW

Displays the actual calculated effective power of the motor. Basis for calculation are the motor
data P201...P209.

P728

Input voltage

(Input voltage)

0 ... 1000 V

Displays the actual mains voltage at the FI input.

P729

Torque

(Torque)

-400 ... 400 %

Displays the actual calculated torque. Basis for calculation are the motor data P201...P209.

P730

Field

(Field)

0 ... 250 %

Displays the actual field in the motor as calculated by the inverter. Basis for calculation are the
motor data P201...P209.

P731

Parameter set

(Actual parameter set)

0 ... 3

Shows the actual operating parameter set.

0 = Parameter set 1

1 = Parameter set 2

2 = Parameter set 3

3 = Parameter set 4

P732

U phase current

(U phase current)

S

0.0 ... 999.9 A

Displays the actual U phase current.

NOTE:

This value can deviate somewhat from the value in P719, due to the measurement
procedure used, even with symmetrical output currents.

P733

V phase current

(V phase current)

S

0.0 ... 999.9 A

Displays the actual V phase current.

NOTE:

This value can deviate somewhat from the value in P719, due to the measurement
procedure used, even with symmetrical output currents.

P734

W phase current

(W phase current)

S

0.0 ... 999.9 A

Displays the actual W phase current.

NOTE:

This value can deviate from the value in P719, due to the measurement procedure
used, even with symmetrical output currents.

P735

Reserved

P736

Link voltage

(DC link voltage)

0 ... 1000 V DC

Displays the actual link voltage.