beautypg.com

1 control terminals – NORD Drivesystems BU0180 User Manual

Page 35

background image

2 Assembly and installation

BU 0180 GB-0914

Pre-series version

35

2.8.1

Control terminals

Terminal X3:

FI type

SK 180E

SK 190E

Labelling

Pin

1

39

TF-, motor thermistor (PTC) connection

2

38

TF+, motor thermistor (PTC) connection

Terminal X4:

FI type

SK 180E

SK 190E

(ASI)

Labelling

Pin

1

11

10V, reference voltage output

2

14

AIN1, analog input 1 / DIN4, digital input 4

3

16

AIN2, analog input 2 / DIN5, digital input 5

4

12 / 40

AGND / 0 V, reference potential for analog signals*

GND / 0 V, reference potential for digital signals

5

43

24 V, power supply output

6

21

DIN1 / digital input 1

7

22

DIN2 / digital input 2

8

23

DIN3, digital input 3

9

1

DOUT1, digital output 1

10

40

GND / 0 V, reference potential for digital signals

11

3

DOUT2, digital output 2

12

40

GND / 0 V, reference potential for digital signals

13

77

SYS H, system bus +

14

78

SYS H, system bus-

*) the analog and digital reference voltages are internally bridged and are therefore identical

Terminal X5 (only SK 190E):

FI type

SK 180E

SK 190E

(ASI)

Labelling

Pin

1

84

ASI+, AS interface+

2

85

ASI-, AS interface-