5 Commissioning

BU 0180 GB-0914

Pre-series version

73

Procedure for SK 190E:

Ensure power supply of the ASi interface via the yellow ASi cable.

Disconnect the AS-i master during addressing

Set the address

≠ 0

Do not doubly assign addresses

Normal hand-held units can be used for the addressing of the frequency inverter. Typical manufacturers are
Pepperl+Fuchs (e.g.: VBP-HH1-V3.0-V1) and IFM (E.g.: AC1154).

The following lists the possibilities for the practical implementation of addressing an SK 190E with an
addressing box.

Version 1
With

a

normal

addressing

device

(equipped

with

an

M12

plug

for

connection to the AS-i bus) the AS-i can
be integrated into the AS-i network via a
suitable access point. The prerequisite for
this is that the AS-i master can be
switched off.










Version 2
With an addressing unit (equipped with
an M12 plug for connection to the AS-i
bus and an additional M12 plug for an
external power supply), the addressing
unit can be directly connected into the
AS-i cable.

NOTE

With the SK 190E a battery-operated addressing device is sufficient.

AS-i addressing unit

AS-i -

MASTER

AS-i -

Power

AS-i addressing unit

AS-i cable