4 electrical data br, Electrical data br – NORD Drivesystems BU0180 User Manual
Page 27
2 Assembly and installation
BU 0180 GB-0914
Pre-series version
27
2.3.4
Electrical data BR
Internal
Inverter ID
SK 1x0E-
…
Resistor type
(IP54)
Resistance
Max. continuous
output / limit**
(P
n
)
Energy
consumption*
(P
max
)
Connecting cable
or terminals
750…111-323-A
SK BRI4-1-200-100
Part. No. 275272008
200
100 W / 25%
1.0 kWs
Silicone
conductor
2x 0.75 mm
2
approx. 275 mm
151…221-340-A
SK BRI4-1-400-100
Part. No. 275272012
400
100 W / 25%
1.0 kWs
*) Maximum once within 10 s**
**) In order to prevent impermissible heating of the device, the continuous power is limited
to 1/4 of the rated power of the brake resistor.
This also has a limiting effect on the power consumption.
External
Inverter ID
SK 1x0E-
…
Resistor type
(IP67)
Resistance
Max. continuous
power
(P
n
)
Energy
consumption*
(P
max
)
Connecting cable
or terminals
750…111-323-A
SK BRE4-1-100-100
Part. No. 275273005
100
100 W
2.2 kWs
FEP flex
3x 1.9 mm
2
AWG 14/19
approx. 350 mm
151…221-340-A
SK BRE4-1-200-100
Part. No. 275273008
200
100 W
2.2 kWs
*)Maximum once within 120 s