NORD Drivesystems BU0180 User Manual
Page 134
SK 180E Manual for frequency inverters
134
Pre-series version
BU 0180 GB-0914
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P748
CANopen status
(CANopen status
(system bus status))
0000 ... FFFF
(hex)
or
0 ... 65535
(dec)
Shows the status of the system bus.
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
Bit 9:
Bit 10:
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
System bus
→ Bus module online (field bus module, e.g.: SK xU4-PBR)
System bus
→ Additional module 1 online (I/O - module, e.g.: SK xU4-IOE)
System bus
→ Additional module 2 online (I/O - module, e.g.: SK xU4-IOE)
The protocol of the CAN module is 0 = CAN / 1 = CANopen
Vacant
"Bootup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State
Bit 10
Bit 9
Stopped
Pre- Operational
Operational
0
0
1
0
1
0
P749
Status of DIP switches
(Status of DIP switches)
0000 ... 0007
(hex)
or
0 ... 007
(dec)
This parameter shows the actual setting of the FI DIP switch "S1" (See Section 5.2.2.2)
Bit 0:
Bit 1:
Bit 2:
DIP switch 1
DIP switch 2
DIP switch 3