beautypg.com

NORD Drivesystems BU0180 User Manual

Page 134

background image

SK 180E Manual for frequency inverters

134

Pre-series version

BU 0180 GB-0914

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P748

CANopen status

(CANopen status

(system bus status))

0000 ... FFFF

(hex)

or

0 ... 65535

(dec)

Shows the status of the system bus.

Bit 0:

Bit 1:

Bit 2:

Bit 3:

Bit 4:

Bit 5:

Bit 6:

Bit 7:

Bit 8:

Bit 9:

Bit 10:

24V Bus supply voltage

CANbus in "Bus Warning" status

CANbus in "Bus Off" status

System bus

→ Bus module online (field bus module, e.g.: SK xU4-PBR)

System bus

→ Additional module 1 online (I/O - module, e.g.: SK xU4-IOE)

System bus

→ Additional module 2 online (I/O - module, e.g.: SK xU4-IOE)

The protocol of the CAN module is 0 = CAN / 1 = CANopen

Vacant

"Bootup Message" sent

CANopen NMT State

CANopen NMT State

CANopen NMT State

Bit 10

Bit 9

Stopped
Pre- Operational
Operational

0
0
1

0
1
0

P749

Status of DIP switches

(Status of DIP switches)

0000 ... 0007

(hex)

or

0 ... 007

(dec)

This parameter shows the actual setting of the FI DIP switch "S1" (See Section 5.2.2.2)

Bit 0:

Bit 1:

Bit 2:

DIP switch 1

DIP switch 2

DIP switch 3