3 100hz characteristic curve (only 400v devices) – NORD Drivesystems BU0180 User Manual
Page 175
9 Additional Information
BU 0180 GB-0914
Pre-series version
175
9.8.3
100Hz characteristic curve (only 400 V devices)
( Variation 01:20:00)
An operating point 100 Hz/400 V can be selected
for a greater speed adjustment range with up to a
ratio of 1:20. Special motor data are required (see
below) that differ from the normal 50 Hz data. It
must be ensured in this case that a constant torque
is generated across the entire adjustment range
but that it is smaller than the nominal torque for 50
Hz operation.
The advantage, in addition to the greater speed
adjustment
range,
is
the
improved
motor
temperature behaviour. An external fan is not
absolutely essential for smaller output speed
ranges.
The following data refer to a 230/400 V motor
winding. They apply for IE1 or IE2 motors. It should be noted that these details may deviate slightly, as
motors are subject to certain manufacturing tolerances. It is recommended that the resistance of the
connected motor is measured by the frequency inverter (P208 / P220).
Frequency inverter type
Parameterisation data of frequency inverter
F
N
[Hz]
n
N
[min
-1
]
I
N
[A]
U
N
[V] P
N
[kW] cos
Circuit
R
St
[
]
IE1 Motors
SK…63S/4 SK 1x0E-250-340-B
100
2880
0.95
400
0.25
0.63
Delta
47.37
SK…71S/4 SK 1x0E-370-340-B
100
2895
1.07
400
0.37
0.71
Delta
39.90
SK…71L/4 SK 1x0E-550-340-B
100
2900
1.59
400
0.55
0.72
Delta
22.85
SK…80S/4 SK 1x0E-750-340-B
100
2910
2.0
400
0.75
0.72
Delta
15.79
SK…80L/4 SK 1x0E-111-340-B
100
2910
2.8
400
1.1
0.74
Delta
10.49
SK…90S/4 SK 1x0E-151-340-B
100
2925
3.75
400
1.5
0.76
Delta
6.41
SK…90L/4 SK 1x0E-221-340-B
100
2920
4.96
400
2.2
0.82
Delta
3.99
IE2 Motor
SK…80SH/4SK 1x0E-750-340-B
100
2930
1.9
400
0.75
0.70
Delta
9.34
SK…80LH/4 SK 1x0E-111-340-B
100
2920
2.56
400
1.1
0.73
Delta
6.30
SK…90SH/4SK 1x0E-151-340-B
100
2930
3.53
400
1.5
0.79
Delta
4.96
SK…90LH/4 SK 1x0E-221-340-B
100
2925
4.98
400
2.2
0.79
Delta
3.27
Frequency inverter type
Performance data at rated point*
P
B
[kW]
n
B
[min
-1
]
M
B
[Nm]
SK…63S/4 SK 1x0E-250-340-B
0.25
2840
0.90
SK…71S/4 SK 1x0E-370-340-B
0.37
2855
1.23
SK…71L/4 SK 1x0E-550-340-B
0.55
2860
1.83
SK…80S(H)/4 SK 1x0E-750-340-B
0.75
2885 (2905)
2.48 (2.4)
SK…80L(H)/4 SK 1x0E-111-340-B
1.1
2900 (2905)
3.62 (3.6)
SK…90S(H)/4 SK 1x0E-151-340-B
1.5
2925 (2925)
4.90 (4.8)
SK…90L(H)/4 SK 1x0E-221-340-B
2.2
2920 (2925)
7.20 (7.1)
* Values in brackets apply for IE2 motors
Kennlinie 100 Hz (4-poliger Motor)
0
0,2
0,4
0,6
0,8
1
1,2
0
10
20
30
40
50
60
70
80
90
100
Frequenz / Hz
M/Mn
M/M
N
P/P
N
0
1445
2890
Frequency
[Hz]
Speed
[1/min]
100 Hz characteristic curve (4-pole motor)