9.8 Motor data - characteristic curves

9.8.1

50Hz characteristic curve

( Variation 1:10)

a) 115V / 230 V frequency inverter

The motor used for 50 Hz operation can be operated
up to its rated point 50 Hz/230 V with the nominal
torque. In spite of this, operation above 50Hz is
possible, however the output torque reduces in a
non-linear manner (see following diagram). Above
the rated point, the motor enters its field weakening
range, as the voltage cannot be raised over 230 V
when the frequency is increased above 50 Hz.
Because of the mains voltage, maximum 230 V are
available.

The following data is based on an output of 4 kW
using a 230/400 V motor winding. They apply for IE1
or IE2 motors. It should be noted that these details
may deviate slightly, as motors are subject to certain
manufacturing tolerances. It is recommended that the
resistance of the connected motor is measured by the frequency inverter (P208 / P220).

Frequency inverter type

Parameterisation data of frequency inverter

F

N

[Hz]

n

N

[min

-1

]

I

N

[A]

U

N

[V]

P

N

[kW] cos

Circuit

R

St

[

]

IE1 Motors

SK…71S/4 TI 4 - SK 1x0E-250-323-B*

50

1365

1.3

230

0.25

0.79

Delta

39.90

SK…71L/4 TI 4 - SK 1x0E-370-323-B*

50

1380

1.89

230

0.37

0.71

Delta

22.85

SK…80S/4 TI 4 - SK 1x0E-550-323-B*

50

1385

2.62

230

0.55

0.75

Delta

15.79

SK…80L/4 TI 4 - SK 1x0E-750-323-B*

50

1395

3.52

230

0.75

0.75

Delta

10.49

SK…90S/4 TI 4 - SK 1x0E-111-323-B

50

1410

4.78

230

1.1

0.76

Delta

6.41

IE2 Motor

SK…80SH/4 TI 4 - SK 1x0E-550-323-B*

50

1415

2.39

230

0.55

0.70

Delta

9.34

SK…80LH/4 TI 4 - SK 1x0E-750-323-B*

50

1410

3.12

230

0.75

0.75

Delta

6.30

SK…90SH/4 TI 4 - SK 1x0E-111-323-B

50

1430

4.26

230

1.1

0.80

Delta

4.96

* the same data apply for the use of the 115V version of the SK1x0E

Frequency inverter type

Performance data at rated point**

P

B

[kW]

n

B

[minP

-1P

]

M

B

[Nm]

SK…71S/4 TI 4 - SK 1x0E-250-323-B*

0.25

1380

1.73

SK…71L/4 TI 4 - SK 1x0E-370-323-B*

0.37

1380

2.56

SK…80S(H)/4 TI 4 - SK 1x0E-550-323-B*

0.55

1375 (1420)

3.82 (3.73)

SK…80L(H)/4 TI 4 - SK 1x0E-750-323-B*

0.75

1375 (1415)

5.21 (5.06)

SK…90S(H)/4 TI 4 - SK 1x0E-111-323-B

1.1

1395 (1435)

7.53 (7.32)

* the same data apply for the use of the 115V version of the SK1x0E

** Values in brackets apply for IE2 motors

50 Hz characteristic curve (4-pole motor)

0

0,2

0,4

0,6

0,8

1

1,2

0

10

20

30

40

50

60

70

80

90

100

Frequenz / Hz

Drehzahl / 1/min

M/Mn

M/M

N

P/P

N


0

1445

2890

Frequency

[Hz]
Speed
[1/min]