3.12 Measuring Power (/PWR1 Option)

Power Monitor Function

Measure the measurement elements of electrical power. Set an expression on a
computation channel, and then start the computation to begin the measurement.
In addition, by using other operators, you can measure the maximum, minimum, average
and electric energy.

Measurement Element

Symbol

Description

Active or regenerative power

WAT

Power values without the low-cut

function applied.

Active power

WATP

Regenerative power

WATN

Reactive power

VAR

Reactive power (LAG)

VARP

Reactive power (LEAD)

VARN

Apparent power

VA

Active or regenerative power (low-cut)

_WAT_

Power values with the low-cut

function applied. The electric energy

is measured by summing these

measurement elements.
The low-cut function sets the

measured value to 0 when the

measured value is less than the set

low-cut power. With no load, this

function prevents the influence of noise

present in each measurement element

from accumulating in the power

consumption (Wh) calculation.

Active power (low-cut)

_WATP_

Regenerative power (low-cut)

_WATN_

Reactive power (low-cut)

_VAR_

Reactive power (LAG; low-cut)

_VARP_

Reactive power (LEAD; low-cut)

_VARN_

Apparent power (low-cut)

_VA_

Voltage (V1)

VOL1

This is the voltage.

Voltage (V2)

VOL2

This is the voltage. This is only valid

for single-phase three-wire systems.

Voltage (V3)

VOL3

This is the voltage. This is only valid

for three-phase three-wire systems.

Current (I1)

CUR1

This is the current.

Current (I2)

CUR2

This is the current. This is only valid for

single-phase three-wire systems.

Current (I3)

CUR3

This is the current. This is only valid for

three-phase three-wire systems.

Frequency

HZ

This is the frequency.

Power factor

PF

This is the power factor.

Measuring Electric Energy

The electric energy is calculated by summing the measured values of the power
measurement channels. To avoid the influence of noise in this calculation, normally use
the low-cut function. On the FX, sum powers to which the low-cut function has been
applied (_WAT_, _WATP_, _WATN_, _VAR_, _VARP_, _VARN_, and _VA_ in the above
table) to measure the electric energy. You can set the low-cut point to any value that you
want.

• Computation Channels

You can write expressions in computation channels to measure the electric energy.

You have to set an expression—one which will be used to sum the measured power
values—in a computation channel. The sum is set using the TLOG expression and
the timer (see example 4 in this section). The TLOG expressions are shown in the
following table.