10.1 A List of Messages
There are cases in which error codes and messages are displayed on the screen during
operation. A list of the possible error codes and messages are given in the table below.
Communication error codes and messages are also listed.
Error responses to communication commands are output in English.
Errors Related to Parameter Settings
•
Setting Errors
Code
Message
Explanation/Countermeasures/Ref. section
1
System error.
Contact your nearest YOKOGAWA dealer.
2
Incorrect date or time setting.
Enter a correct value.
3
A disabled channel is selected.
Specify a channel that is not set to Skip or Off.
Specify a channel that is installed.
4
Incorrect function parameter.
See chapter 3 the communication manual.
5
The input numerical value exceeds the set range.
Enter a proper value.
6
Incorrect input character string.
Enter a proper character string.
7
Too many characters.
Enter the correct number of characters.
8
Incorrect input mode.
Specify a correct mode.
See section 3.3.
9
Incorrect input range code.
Specify a correct range code.
See section 3.3.
11
Range settings are not same within the selected channels.
Specify channels with the same range setting.
See section 3.9.
21
Cannot set an alarm for a skipped channel.
Cannot be specified on channels set to Skip.
See section 3.7.
22
The upper and lower span limits are equal.
Cannot be set to the same value.
See section 3.3.
23
The upper and lower scale limits are equal.
Cannot be set to the same value.
See section 3.3.
24
The lower limit of the span band is greater than the upper limit. Set the lower limit less than the upper limit.
See section 3.3.
25
The lower limit of the scale band is greater than the upper limit. Set the lower limit less than the upper limit.
See section 3.3.
26
The scale band is wider than 16 decades of the entire scale.
The Log scale width must be 15 decades or less.
See section 3.13.
27
The scale band is less than 1 decade of the entire scale.
The absolute value of the difference between the Log
scale upper limit’s exponent and the Log scale lower
limit’s exponent must be at least 1. See section 3.13.
28
Incorrect combination of mantissa and exponent.
Log scale range setting error.
See section 3.13.
30
The partial boundary value exceeds the range of the span.
Set the boundary value in the range of “the minimum
span value + 1 digit” to “the maximum span value – 1
digit.”
See section 5.9.
31
Partial-expansion display is set ON for a SKIPPED channel or
a LOG channel.
Cannot be specified on channels set to Skip.
See sections 3.3 and 5.9
35
The upper and lower limits of the display band are equal.
Set the upper limit greater than the lower limit + 5.
See section 5.6.
36
The lower limit of the display band is greater than the upper
limit.
Set the upper limit greater than the lower limit + 5.
See section 5.6.
37
The display band is narrower than 4% of the entire display.
Set the upper limit greater than the lower limit + 5.
See section 5.6.
38
The lower limit of display position is greater than the upper
limit.
In the Log scale settings, the channel’s color scale band
display position has been set so that Scale_L is greater
than or equal to Scale_U.
See section 3.13.
40
Incorrect group set character string.
Check the syntax.
See section 5.1.