6-11

IM 04L21B01-01EN

Saving and Loading Data

3

2

1

4

5

6

7

8

9

10

11

12

13

14

App

Index

• Stopping the Recording (Memory Stop)

1.

Press

STOP. A confirmation window is displayed.

If you are using the batch function, the batch name and comment are displayed

on the screen.

2.

Select

Yes using the arrow keys and press DISP/ENTER.

If the FX is equipped with computation functions (/M1, /PM1, and /PWR1

options), select

Mem+Math or Memory, and then press DISP/ENTER.

The internal memory icon in the status display section changes to the stop icon.

• Saving the Data in the Internal Memory Collectively or Selectively

through Key Operation

See section 4.8.

Explanation

• Operations That Start Simultaneously with Memory Start

• Waveform display updating on the trend display.
• Report (/M1, /PM1, and /PWR1 options)
• The computation function (/M1, /PM1, and /PWR1 options) can be configured to

start simultaneously with memory start.

See section 9.4.

• Operations That Stop Simultaneously with Memory Stop

• Waveform display updating on the trend display.
• Report (/M1, /PM1, and /PWR1 options)
• Computation function (/M1, /PM1, and /PWR1 options): When selected in the

procedure described above.

• Performance While Data Is Being Saved

If the internal memory or external storage medium is continuously accessed, the

following phenomena may occur.
• Files being saved to the external storage medium drop out.
• Accessing the FX through communications takes a long time
In such case, take the following measures.
• If you are creating data files at short intervals consecutively using the event action

function, increase the data file save interval.

• If you are creating numerous files in a single directory on the external storage

medium, change the destination directory name at approximately every 1000 files.

6.4 Starting/Stopping the Recording and Saving the Measured data