beautypg.com

Process value menu – Watlow EZ-ZONE PM Integrated Controller User Manual

Page 77

background image

Watlow EZ-ZONE

®

PM Integrated Controller

74

Chapter 6 Setup Page

Setup Page

Dis-

play

Parameter Name

Description

Range

Default

Modbus Rela-

tive

Address

CIP

Class

Instance

Attribute

hex (dec)

Pro-

fibus

Index

Param-

eter ID

Data

Type

&

Read/

Write

[iP;10]
[ip.10]

Linearization (1 to 2)

Input Point 10

Set the value that will be

mapped to output 10.

-1,999.000 to 9,999.000

9.0

Instance 1

Map 1 Map 2

- - - -

3592

Instance 2

Map 1 Map 2

- - - -

3662

0x86 (134)

1 to 2

0x11 (17)

175

34017 float

RWES

[oP;10]
[op.10]

Linearization (1 to 2)

Output Point 10

Set the value that will be

mapped to input 10.

-1,999.000 to 9,999.000

9.0

Instance 1

Map 1 Map 2

- - - -

3612

Instance 2

Map 1 Map 2

- - - -

3682

0x86 (134)

1 to 2

0x1B (27)

176

34027 float

RWES

[``Pu]
[`Set]

Process Value Menu

[``Fn]
[ Fn]

Process Value (1 to 2)

Function

Set the function that will

be applied to the source

or sources.

Note:

Differential and Ratio not
available using instance 2.

[`oFF]

Off (62)

[usla]

Vaisala RH Compen-

sation (1648)

[`W;b]

Wet Bulb/Dry Bulb

(1369)

[`S;bA]

Sensor Backup (1201)

[rAti]

Ratio (1374)

[diFF]

Differential (1373)

[root]

Square Root (1380)

[`alt]

**Pressure to Altitude

(1649)

Off

Instance 1

Map 1 Map 2

- - - -

3320

Instance 2

Map 1 Map 2

- - - -

3390

0x7E (126)

1 to 2

0x15 (21)

123

26021 uint

RWES

[p;unt]
[P.unt]

Process Value (1 to 2)

Pressure Units**

Set the units that will be

applied to the source.

[`psi]

Pounds per Square

Inch (1671)

[pasc]

Pascal (1674)

[atm]

Atmosphere (1675)

[mbr]

Millibar (1672)

[torr]

Torr (1673)

PSI

Instance 1

Map 1 Map 2

- - - -

3334

Instance 2

Map 1 Map 2

- - - -

3404

0x7E (126)

1 to 2

0x1C (28)

- - - -

26028 uint

RWES

[a;unt]
[A.unt]

Process Value (1 to 2)

Altitude Units**

Set the units that will be

applied to the source.

[`Hft]

Kilofeet (1677)

[``ft]

Feet (1676)

HFt

Instance 1

Map 1 Map 2

- - - -

3336

Instance 2

Map 1 Map 2

- - - -

3406

0x7E (126)

1 to 2

0x1D (29)

- - - -

26029 uint

RWES

[`b;pr]
[ b.Pr]

Process Value (1 to 2)

Barometric Pressure**

Set the units that will be

applied to the source.

10.0 to 16.0

14.7

Instance 1

Map 1 Map 2

- - - -

3338

Instance 2

Map 1 Map 2

- - - -

3408

0x7E (126)

1 to 2

0x1E (30)

- - - -

26030 float

RWES

[`Fil]
[ FiL]

Process Value (1 to 2)

Filter

Filtering smooths out

the output signal of this

function block. Increase

the time to increase fil-

tering.

0.0 to 60.0 seconds

0.0

Instance 1

Map 1 Map 2

- - - -

3330

Instance 2

Map 1 Map 2

- - - -

3400

0x7E (126)

1 to 2

0x1A (26)

- - - -

26026 float

RWES

Note:
Some values will be rounded off to fit in the four-character display. Full values can be read
with other interfaces.

R: Read

W: Write

E:

EEPROM

S:

User

Set

** Pressure Altitude calculation is based on the International Standard Atmosphere 1976