Devicenet™ communications, Module status (cont .), Activity status – Watlow EZ-ZONE PM Integrated Controller User Manual
Page 40: Link status
Watlow EZ-ZONE
®
PM Integrated Controller
•
37
•
Chapter 2 Install and Wire
Warning:
Óç
Use National Electric (NEC) or other
country-specific standard wiring and
safety practices when wiring and
connecting this controller to a power
source and to electrical sensors or
peripheral devices. Failure to do so
may result in damage to equipment
and property, and/or injury or loss
of life.
Note:
Maximum wire size termination and
torque rating:
• 0.0507 to 3.30 mm
2
(30 to 12
AWG) single-wire termination or
two 1.31 mm
2
(16 AWG)
• 0.8 Nm (7.0 lb.-in.) torque
Note:
Adjacent terminals may be labeled
differently, depending on the model
number.
Note:
To prevent damage to the control-
ler, do not connect wires to unused
terminals.
Note:
Maintain electrical isolation between
analog input 1, digital input-outputs,
switched dc/open collector outputs
and process outputs to prevent
ground loops.
Note:
The control output common termi-
nal and the digital common terminal
are referenced to different voltages
and must remain isolated.
Note:
This Equipment is suitable for use in
CLASS I, DIVISION 2, Groups A, B,
C and D or Non-Hazardous locations
only. Temperature Code T4A
Warning:
ç
Explosion Hazard - Dry contact clo-
sure Digital Inputs shall not be used
in Class I Division 2 Hazardous Loca-
tions unless switch used is approved
for this application.
Warning:
ç
Explosion Hazard – Substitution of
component may impair suitability
for CLASS I, DIVISION 2.
Warning:
ç
Explosion Hazard - Do not discon-
nect while the circuit is live or
unless the area is known to be free
of ignitable concentrations of flam-
mable substances.
Module Status (cont .)
Indicator State
Summary
Requirement
Steady Red
Major fault
If the device has detected a non-recoverable
major fault, the module status indicator shall
be steady red.
Flashing Green / Red Self-test
While the device is performing its power up
testing, the module status indicator shall be
flashing green / red.
Activity Status
Indicator State
Summary
Requirement
Flashing Green
Detects activity
If the MAC detects activity, the LED will be
flashing green.
Red
- - - -
If the MAC detects a collision, the LED will
be red.
Link Status
Indicator State
Summary
Requirement
Steady Off
Not powered,
unknown link speed
If the device cannot determine link speed
or power is off, the network status indicator
shall be steady off.
Green
- - - -
If cable is wired and connected correctly, the
LED will be Green.
DeviceNet™ Communications
CAN_L
V-
V+
CH
SH
CL
V-
T2
S2
R2
Slot B, E
V+
CAN_H
shield
Terminal
Signal
Function
V+
V+
DeviceNet™ power
CH
CAN_H
positive side of Devi-
ceNet™ bus
SH
shield
shield interconnect
CL
CAN_L
negative side of Devi-
ceNet™ bus
V-
V-
DeviceNet™ power
return
• Communications instance 2
Slot B (PM [6] _ _ _ _ _ - [5] _ _ _ _ _ _ )
Slot E (PM [4,8,9] _ _ _ _ _ - [5] _ _ _ _ _ _ )