Chapter 1 Overview

EZ-ZONE

®

PM Integrated Model 1/16 DIN With Limit, System Diagram

Without Communications Card (Slot B)

Note:

Number of inputs and outputs and various combinations of the same will vary

depending upon part number; see ordering matrix for more detail.

EZ Key

Programmable Event

Digital Output (or Input) 5 & 6

(optional) none, switched dc

Digital Input (or Output) 5 & 6

(optional) none, switch, volts dc

Limit Controller

Board

(optional)

Slot B

Input

Functions

Output

Functions

- None

- Limit reset

- Idle set point

- Tune

- Alarm clear, request

- Force alarm

- Silence alarm

- Manual/auto mode

- Control outputs off

- Remote set point

enable

- Lock keypad

- TRU-TUNE+

®

disable

- Loop & alarms off

- Profile disable

- Profile hold/resume

- Profile start

- Profile start/stop

- Restore user settings

- Event inputs

Output Status

5

1

3

2

4

Indicates Zone

Address

Indicates I/O

Status

Zone

Address

Analog Input 1

none, Thermocouple, RTD (100Ω,

1kΩ), Thermistor 5kΩ, 10kΩ, 20kΩ,

40kΩ) Process (V, mV, mA) or 1k

Potentiometer

Output 1

none, switched dc/open collector, 5A

mechanical relay (form C), process

(V, mA), or 0.5A SSR (form A)

Output 2

none, 15A NO-ARC, switched dc,

5A mechanical relay (form A), or

0.5A SSR (form A)

PID

Controller

(Optional -

Ramp/Soak max 4

files, 40 steps)

Slots A

(Optional)

Input Sensor

off, heat, cool

alarm, retransmit,

duplex, event

off, heat, cool

alarm, event

off, heat, cool

alarm, retransmit,

duplex or event

Limit

off, heat, cool

alarm, event

Modbus

Address 1 - 247

Standard Bus

Zone Address

1 - 16

Supervisory &

Power Board

Slot C

EIA-485 Communication

Standard Bus

(optional Modbus RTU)

RUI, EZ-ZONE

Controllers, PLC, PC

or HMI

Output 3

none, switched dc/open collector, 5A

mechanical relay (form C), process

(V, mA), or 0.5A SSR (form A)

Output 4

5A mechanical relay (form A)

Analog Input 2

none, CT, Thermocouple, RTD (100

Ω, 1kΩ), Thermistor 5kΩ, 10kΩ,

20kΩ, 40kΩ) Process (V, mV, mA)

or 1k Potentiometer

Input Sensor

If Limit, this output must

be Limit

6

Integrated PID and Limit Controller
Reduces wiring time and termination complexity compared to connecting separate products
Reduces panel space
Reduces installation costs
Increases dependability with backup control sensor operation
Increases user and equipment safety for over-under temperature conditions