beautypg.com

IAI America XSEL-S User Manual

Page 31

background image

5. V

ision System I/F Function Setting

25

[Setting 2] Ethernet Operation Prescription [compulsory] (I/O Parameters No.129)

Set the Ethernet operation prescription in I/O Parameters No.129.
Set the bits 4-7 to “1”.

I/O Parameter No.129 = 10

H

I/O Parameters No.129

Bit 4-7

Bit 0-3

TCP/IP Message Communication is Used

Set Value=1

Set Value 0

[Setting 3] Controller Network Address Setting [compulsory]

(I/O Parameters No.132 to 143,146)
Set the I/O Parameters No.132 to 143 and 145 to 148 following the network
environment.

I/O Parameters No.132 to 135 Self IP Address (IP address of X-SEL)
I/O Parameters No.136 to 139 Subnet Mask
I/O Parameters No.140 to 143 Default Gateway

I/O Parameters No.146

Free-for-User Channel 32 (TCP/IP)
Self-Port Number

(Note)

Set it in
accordance with
the network
environment to
be used

(Note) Do not change I/O Parameter No.146 from “64513” (initial setting value) when using

EZ-110XL.

[Setting 4] Vision System Network Address Setting [compulsory] (I/O Parameters No.160 to 164)

Set the parameters such as the network address of the vision system to be connected in
I/O Parameters No.160 to 164.
Refer to the IP address settings on the controller side (I/O Parameters No.132 to 134) for
the IP address to set it to have the controller and the vision system exist on the same
network.
(Note)

When setting the IP addresses, be sure not to duplicate the entire address.

(Example) IP address of Vision System 192.168. 0. 11 (I/O Parameter No.160 to 163)

IP address of X-SEL

192.168. 0. 12 (I/O Parameter No.132 to 135)

I/O Parameters
No.160 to 163

Vision System I/F connected IP address

Input Vision System IP
address setting value

I/O Parameters
No.164

Vision System I/F Connected Port Number

(Example)
Cognex

:3000

H

Keyence

:8500

H

Continue to Section 5.4 to complete the setting procedures.

Avoid duplication