Error treatment, 1 common errors for all vision systems – IAI America XSEL-S User Manual
Page 106
7. Error
T
reatment
100
7. Error Treatment
7.1
Common Errors for All Vision Systems
Following explains the details of the errors and how to deal with it when an error number is
displayed.
Refer to the corresponding error number to have an appropriate treatment when an error is issued.
(Note) Refer to Section 7.2 if an error is generated while in the simple (dedicated) calibration with
using EX-110XL.
Error No.
415
Name
Unsupported Identification Code Received Error (Tracking and Vision System I/F data
communication)
Description
An error is detected in the identification code of a message received from the vision
system.
Treatment
Identification code is a fixed value.
8.1 Check and correct the communication format settings.
Error No.
416
Name
Received Message Error(Tracking and Vision System I/F data communication)
Description
An error is detected in the message received from the vision system.
Select “Monitor” o “Error Detail” from the menu in X-SEL PC Software.
The cause of the error is displayed in Info 1 and Info 2 in Error Detail.
Check the message settings on the Vision System side following the table below.
Info1
Info2
Cause
Treatment Detail
1h
-
Header
The received message header is wrong. Check the
following parameter settings.
* The setting differs depending on the vision system
supplier.
x
I/O Parameter No.352, Bits 0 to 7: when set to 0 or 1
o
Check the settings in I/O Parameter No.353, Bits 8 to
15. (Cognex : 3C
H
, OMRON : 39
H
)
x
I/O Parameter No.352, Bits 2 to 7: when set to 0
o
Check the settings in I/O Parameter No.353, Bits 16
to 31. (Keyence : 5431
H
)
2h
-
Identification
Code
There is no identification code in the received
message, or a character other than 0 to 9 (ASCII value)
is set to the identification code.
Check the identification code setting for the message.
[Refer to 8.1 Communication Format Setting Values]
3h
-
Work
piece
There is no work piece quantity data in the received
message, or a character other than 0 to 9 (ASCII value)
is set to the work piece quantity.
Check the work piece quantity data setting for the
message.
[Refer to 8.1 Communication Format Setting Values]
Treatment