7. Error
T
reatment
106
Check the value in No.1053 and find the corresponding error number to take an appropriate
counteraction.
Value in No.1053 51
Name
31ch (TELNET) Non-Open Error
Description
Channel 31 could not open.
Treatment
Check the vision system power supply and Ethernet cable layout.
Value in No.1053 52
Name
32ch (Robot Movement Command Port) Non-Open Error
Description
Channel 32 could not open.
Treatment
Check the vision system power supply and Ethernet cable layout.
Value in No.1053 53
Name
TELNET Login Process Message Error
Description
A normal value was not returned from the vision system
Treatment
Check the vision system power supply, Ethernet cable layout and also the status of the
vision system if it is online and in the process of a job.
Value in No.1053 54
Name
TELNET Login Process Read Error
Description
The returned value from the vision system was not received.
Treatment
Check the vision system power supply and Ethernet cable layout.
Check the value in No.1055 shown in the calibration process status monitor window,
confirm the details of the error in Section 7.3 and take an appropriate counteraction.
Value in No.1053 55
Name
Vision System Reset Command Error
Description
A normal value was not returned from the vision system
Treatment
Check the vision system power supply, Ethernet cable layout and also the status of the
vision system if it is online and in the process of a job.
Value in No.1053 56
Name
Vision System Reset Read Error
Description
The returned value from the vision system was not received.
Treatment
Check the vision system power supply and Ethernet cable layout.
Check the value in No.1055 shown in the calibration process status monitor window,
confirm the details of the error in Section 7.3 and take an appropriate counteraction.