(11) Following the table for EZ-110XL settings in Section 8.1, input and select the necessary data.

(Note) For the details, refer to Cognex Instruction Manual or the enclosed data (Sample.job).

Click “OK”.

(12) Select TCP/IP Settings tag in TCP/IP Setting window.
(13) It is not necessary to input the Server Host Name.
(14) Put the same value to Port as the one input to XSEL I/O Parameter No. 164.
(15) Select CR(13) for Terminator.

Input <00 (Fixed value)

Click Add and the values

available for output can be

selected as the result of the

detection tool and calculation

tool.

(1) Select the number of

detection from the detection

tool and set it.

• Label to be excluded

(put no tick mark)

• Data Type is Integer

• Tick in Fixed Width box and

put 2 to Field Width and the

top 0 to Pad.

(2) Select the calculation result

from the calculation tool and

set it.

• Label to be excluded

(put no tick mark)

• Data Type is Integer

• Tick in Fixed Width box and

put 2 to Field Width and the

top 0 to Pad.

* For the label, input 2

characters for the capturing

work attribute. (If there is

none, input 00.)

(14)

(13)

(15)

(12)

3000