1. Values and Symbols Used in SEL Language

1-1 List of Values and Symbols Used

The various functions required in a program are represented by values and symbols.

Function

Global range

Local range

Remarks

Input port

000 ~ 299 (300)

Varies depending on
the function.

Output port

300 ~ 599 (300)

Varies depending on
the function.

Flag

600 ~ 899 (300)

900 ~ 999 (100)

Variable (integer)

200 ~ 299 (100)

1200 ~ 1299 (100)

1 ~ 99 (99)

1001 ~ 1099 (99)

99 is used for IN, INB,
OUT, OUTB, etc.

Variable (real)

300 ~ 399 (100)

1300 ~ 1399 (100)

100 ~ 199 (100)

1100 ~ 1199 (99)

199 is used for PPUT,
PGET, PARG, etc.

String

300 ~ 999 (700)

1 ~ 299 (299)

Tag number

1 ~ 99 (99)

Subroutine number

1 ~ 99 (99)

Zone number

1 ~ 4 (4)

Pallet number

1 ~ 10 (10)

Axis number

1 ~ 4 (4)

Varies depending on
the function.

Axis pattern

0 ~ 1111

Position number

1 ~ 3000 (3000)

Program number

1 ~ 64 (64)

Step number

1 ~ 6000 (6000)

Task level

NORMAL/HIGH (2)

SIO channel number

1 ~ 1 (1) (Also used for

TP/PC)

Wait timer

1

1-shot pulse timer

16 (Number of timers

that can be operated

simultaneously)

Ladder timer

Local flag (100)

Virtual input port (SEL

system

 SEL user

program)

7000 ~ 7299 (300)

Virtual output port (SEL

user program

 SEL

system)

7300 ~ 7599 (300)

Number of symbol

definitions

1000

Number of times symbol

can be used in commands

5000 (including literals)

Used in common from

any program.

Referenced separately in
each program.
Cleared when the
program is started.

Caution


 Variables 99 and 199 are special variables this system uses in operations.

Avoid using these two variables for general purposes.

 The values in the table represent ranges that can be processed by software.

Items that require physical devices, such as I/O ports and functions relating
to axis number and SIO, will be determined by possible combinations and
models of commercial boards, etc., available for each device application.