I/o parameters – IAI America XSEL-KET User Manual
Page 355

336
INTELLIGENT ACTUATOR
Appendix
1. I/O
Parameters
No. Parameter
name
Default value
(Reference)
Input
range
Unit
Remarks
1 I/O port assignment
type
1
0 ~ 20
0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 (standard I/O) ~ * Ports
are assigned only for the installed adjoining slots, starting from
slot 1 = For safety reasons)
2 Input port start
number with fixed
standard I/O
assignments (I/O1)
000
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
3 Output port start
number with fixed
standard I/O
assignments (I/O1)
300
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
4 Input port start
number with fixed
expanded I/O1
assignments (I/O2)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set) (Slot next to the
standard I/O slot)
5 Output port start
number with fixed
expanded I/O1
assignments (I/O2)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
6 Input port start
number with fixed
expanded I/O2
assignments (I/O3)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
7 Output port start
number with fixed
expanded I/O2
assignments (I/O3)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
8 Input port start
number with fixed
expanded I/O3
assignments (I/O4)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
9 Output port start
number with fixed
expanded I/O3
assignments (I/O4)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
10 Standard I/O error
monitor (I/O1)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
3: Monitor (Monitor only errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
* Some exceptions apply.
11 Expanded I/O1 error
monitor (I/O2)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
3: Monitor (Monitor only errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
* Some exceptions apply.
(Slot next to the standard I/O slot) * Some exceptions apply.
12 Expanded I/O2 error
monitor (I/O3)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
3: Monitor (Monitor only errors relating to 24-V I/O power source)
(Main application version 0.55 or later)
* Some exceptions apply.