IAI America XSEL-KET User Manual
Page 373

354
INTELLIGENT ACTUATOR
Appendix
Axis-Specific Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
94
Zone 3 output number
0
0 ~ 899
Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid) (“0” can be input in PC software version
1.0.0.0 or later or TP application version 1.06 or
later)
95
Zone 4 MAX
0
-99999999 ~
99999999
0.001 mm
Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.
96
Zone 4 MIN
0
-99999999 ~
99999999
0.001 mm
Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.
97
Zone 4 output number
0
0 ~ 899
Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid) (“0” can be input in PC software version
1.0.0.0 or later or TP application version 1.06 or
later)
98~
120
(For extension)
0
~