IAI America XSEL-KET User Manual
Page 403

Appendi
x
INTELLI
GENT A
CTUAT
OR
384
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
A44 Point-data
count
specification error
The specified number of point data is invalid.
A45
Symbol-record count specification error
The specified number of symbol records is invalid.
A46
Variable-data count specification error
The specified number of variable data is invalid.
A48
Error-detail query type 1 error
Error-detail query type 1 is invalid.
A49
Error-detail query type 2 error
Error-detail query type 2 is invalid.
A4A
Monitoring data type error
The data type for monitoring data query is invalid.
A4B
Monitoring-record count specification error
The specified number of records for monitoring data query is invalid.
A4C
Monitoring-operation special command register busy error
The driver special command ACK generated a timeout during
monitoring operation.
A4E
Parameter register busy error at issuance of slave command
The driver special command ACK generated a timeout at issuance of a
slave command.
A4F
Software reset refusal error during operation
Software reset (SIO) is prohibited during operation (program is running,
servo is in use, etc.).
A50
Drive-source recovery request refusal error
The drive-source cutoff factor (error, deadman switch, safety gate,
emergency stop, etc.) has not been removed.
A51
Operation-pause reset request refusal error
The all-operation-pause factor (drive-source cutoff, operation-pause
signal, deadman switch, safety gate, emergency stop, etc.) has not
been removed.
A53
Refusal error due to servo ON
A processing not permitted during servo ON was attempted.
A54
Refusal error due to unsupported function
The function is not supported.
A55
Refusal error due to exclusive manufacturer function
A processing not opened to users other than the manufacturer was
attempted.
A56
Refusal error due to invalid data
The data is invalid.
A57
Program start duplication error
An attempt was made to start a program currently running.
A58
BCD error warning
The BCD value being read may be invalid, or the value being written
(variable 99) may be a negative value, among other reasons.
A59
IN/OUT command port flag error warning
The number of I/O ports (flags) may have exceeded 32, among other
reasons. Check the I/O port (flag) specifications.
A5B
Character-string
value conversion error warning
The specified number of converting characters is invalid or characters
that cannot be converted to value are included.
A5C
Copying-character count error warning with SCPY command
The specified number of copying characters is invalid.
A5D
SCIF open error in non-AUTO mode
The channel was opened in a non-AUTO mode. In the MANU mode, the
PC/TP connection must be forcibly disconnected before opening the
serial channel opened to the user. Exercise caution.
A5E
I/O-port/flag count specification error
The specified number of I/O ports/flags is invalid.
A5F
Fieldbus error (LERROR-ON)
A LERROR-ON was detected.
A60
Fieldbus error (LERROR-BLINK)
A LERROR-BLINK was detected.