3. Power-Source Capacity and Heat Output of the Controller


The power-source capacity and heat output of the controller can be obtained using the formulas
below:

Power-source capacity [VA] = {Motor drive power [W] + Control power-source

capacity [W]}

 Power factor [0.6]

Heat output [W] = Total sum of output stage losses [W] + Control power-source

capacity [W]




Motor Drive Power and Output Stage Loss

Actuator motor wattage Motor drive power [W]

Output stage loss [W]

20 W

15.6

1.58

30 W

27.6

2.07

60 W

83.0

3.93

100 W

140.1

6.12

150 W

196.9

8.30

200 W

252.6

9.12

400 W

477.5

19.76

600 W

698.2

27.20

750 W

912.8

29.77




The control power-source capacity varies as follows, depending on the numbers of controller axes and
brake axes.

Control Power-Source Capacity

No BK

BK X 1

BK X 2

BK X 3

BK X 4

1-axis controller [W]

17.5

27.3

2-axis controller [W]

23.4

33.2

42.9

3-axis controller [W]

29.3

39.1

48.8

58.6

4-axis

controller

[W]

35.3 45.0 54.8 64.5 74.3

(In the above table, the number of controller axes indicates the number of axes connectable to the controller. It is not
the number of axes actually connected.)