IAI America XSEL-KET User Manual
Page 404

Appendi
x
INTELLI
GENT A
CTUAT
OR
385
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
A61
Fieldbus error (HERROR-ON)
A HERROR-ON was detected.
A62
Fieldbus error (HERROR-BLINK)
A HERROR-BLINK was detected.
A63
Fieldbus not ready
Fieldbus ready cannot be confirmed.
A64
SCIF overrun error (SIO bridge)
Communication failure. Check for noise, connected equipment and
communication setting.
A65
SCIF receive error (SIO bridge)
Communication failure. Check for noise, shorted/disconnected
communication cable, connected equipment and communication setting.
A66
SCI overrun error (SIO bridge)
Communication failure. Check for noise, circuit failure and slave card.
A67
SCI framing error (SIO bridge)
Communication failure. Check for noise, shorting, circuit failure and
slave card.
A68
SCI parity error (SIO bridge)
Communication failure. Check for noise, shorting, circuit failure and
slave card.
A69
Data change refusal error during operation
An attempt was made to change data whose change is prohibited during
operation (program is running, servo is in use, etc.).
A6A
Software reset refusal error during write
Software reset is prohibited while data is being written to the flash ROM
or slave parameters are being written.
A6B
Fieldbus error (FBRS link error)
A FBRS link error was detected.
A6C
PC/TP start command refusal error in AUTO mode
Starting from the PC software/TP connector is prohibited in the AUTO
mode.
A6D
P0/P3/FROM-area direct write prohibition error
Direct write to the P0/P3/FROM areas is prohibited.
A6E
Refusal error during write
A processing not permitted while data is being written to the flash ROM
or slave parameters are being written was attempted.
A6F
Driver monitor type mismatch error
The standard DIO board support monitor type/main CPU board FROM
support monitor type does not match the monitor type on the PC
software side (monitor screen selection).