(In the panel window, the three digits after “E” indicate an error number.)C
Error No.
Error name
Description, action, etc.
CAF
Excessive valid axes for palletizing 3-point teaching data
There are too many valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.
CB0
Mismatched valid axes for palletizing 3-point teaching data
The valid axis pattern in the point data for palletizing 3-point teaching does not
match.
CB1
Offset setting error at palletizing 3-point teaching
Zigzag offset (not zero) cannot be set in palletizing 3-point teaching, if the
reference point is the same as the end point of the PX-axis.
CB2
BGPA/EDPA pair-end mismatch error
The BGPA/EDPA syntax is invalid. EDPA was declared before BGPA, or
another BGPA was declared after BGPA without first declaring EDPA.
CB4
Arch-motion Z-axis non-declaration error
Z-axis has not been declared by PCHZ or ACHZ.
CB5
BGPA non-declaration error during palletizing setting
Palletizing setting cannot be performed without first declaring BGPA. Declare
BGPA.
CB6
Palletizing point error
The palletizing points are invalid (no arch motion data other than the Z-axis
component, etc.).
CB7
Arch-trigger non-declaration error
Declare arch triggers using PTRG or ATRG.
CB8
No 3-point teaching setting error at palletizing angle acquisition
The palletizing angle cannot be acquired until setting by palletizing 3-point
teaching is complete.
CB9
PX/PY-axis indeterminable error at palletizing angle acquisition
Angle cannot be calculated because there are too many valid axes in the 3-point
teaching data and thus PX/PY-axes cannot be specified.
CBA Reference-axis/PY/PY-axis
mismatch error at palletizing angle
acquisition
Angle cannot be calculated because the reference axis for angle calculation is
neither of the axes comprising the PX/PY-axes as set by 3-point teaching.
CBB Reference-point/PX-axis
end-point duplication error at palletizing
angle acquisition
Angle cannot be calculated because the reference point of 3-point teaching is
the same as the PX-axis end-point data other than the PZ-axis component and
thus arc tangent cannot be calculated.
CBC
Palletizing motion calculation error
Trapezoid control calculation error for palletizing motion
CBD
MOD command divisor 0 error
“0” was specified as the divisor in the MOD command.
CBE
Target-locus boundary over error
The target position or movement locus exceeded the positioning boundary in the
infinite-stroke mode.
CBF
Positioning distance overflow error
The positioning distance is too large.
If the system is of the absolute encoder specification and it has just been
relocated or when “Error No. C74, Actual-position soft limit over error” has also
generated, the absolute reset may not have been executed correctly and
consequently the servo packet calculation counter may have overflowed due to
a current position error. Perform an absolute reset again according to the
procedure specified in the operation manual.
(The current position cannot be recognized correctly only by clicking “Reset
Encoder Error” on the absolute reset screen. Be sure to perform an absolute
reset by strictly following the specified procedure.)
CC0
Axis mode error
The axis mode is invalid.
CC1
Speed change condition error
An attempt was made to change the speed of an axis whose speed cannot be
changed (axis operating in S-motion, etc.).
CC2
Driver parameter list number error
The driver parameter list number is invalid.
CC3
Angle error
The angle is invalid.