INTELLIGENT ACTUATOR
Part 4 Commands
PSIZ (Check position data size)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional PSIZ
Variable
number
Prohibited CP
[Function] Set an appropriate value in the variable specified in operand 1 in accordance with the
parameter setting.
When “Other parameter No. 23, PSIZ function type” = 0
The maximum number of position data that can be stored in the controller will be set.
(Regardless of whether the data are used or not.)
When “Other parameter No. 23, PSIZ function type” = 1
The number of point data used will be set.
[Example] PSIZ 1
When “Other parameter No. 23, PSIZ function type” = 0
The maximum number of position data that can be stored in variable 1 will be set.
When “Other parameter No. 23, PSIZ function type” = 1
The number of point data currently used will be set in variable 1.