beautypg.com

Chapter 7 how to perform an absolute encoder reset, Chapter 7, How to perform an absolute encoder reset – IAI America XSEL-KET User Manual

Page 71: Preparation, Procedure

background image

52

Part 1 Installation

INTELLIGENT ACTUATOR


Chapter 7 How to Perform An Absolute Encoder Reset


When the absolute-encoder battery voltage of the X-SEL Controller is abnormal or when the battery or
encoder cable is disconnected, an encoder battery error will occur and an absolute encoder reset must be
performed.

This chapter explains how to perform an absolute encoder reset using the PC software. For the absolute-
encoder reset method using the teaching pendant, refer to the operation manual for the teaching pendant.
If your system is of the synchro specification, refer to Appendix, “ Absolute Reset of A Synchro
Controller.”

1. Preparation

(1) PC

A PC in which IAI’s X-SEL PC software (X_SEL.exe) has been installed


(2) Connection cable (the cable supplied with the PC software)

RS232C cross cable (PC-end: female 9-pin, Controller-end: male 25-pin)


(3) All adjustments other than the encoder reset must have been completed.

2. Procedure

(1) Turn off the X-SEL Controller power. Turn on the PC power and wait for the operating system to

be started.


(2) Connect the 9-pin, D-sub connector on one end of the connection cable to the communication

port on the PC, and connect the 25-pin, D-sub connector on the other end to the 25-pin
communication port on the controller.


(3) Turn on the controller power. If an encoder battery error is present but no other adjustments are

pending, the 7-segment LED display will show “ECA1” or "ECA2" indicating that the controller
has detected an encoder battery error.


(4) Start the X-SEL PC software (X_SEL.exe) on the PC. The following explains the operation

steps in the X-SEL PC software.


(5) When the [Connection Confirmation] dialog box is displayed, select the port name you are using

on the PC. Click the [OK] button.

(The software will automatically detect the baud rate.)















This manual is related to the following products: