IAI America XSEL-KET User Manual
Page 166

147
Part 4 Commands
INTELLIGENT ACTUATOR
GVEL (Get speed data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional GVEL
Variable
number
Position
number
CP
[Function] Obtain speed data from the speed item in the position data specified in operand 2, and set
the value in the variable specified in operand 1.
[Example]
GVEL
100
10
Set the speed data at position No. 10 in variable 100.
Position No.
Axis 1
Axis 2
Axis 3
Vel
Acc
Dcl
1 XXX.XXX
XXX.XXX
XXX.XXX
XXX
X.XX
X.XX
2 XXX.XXX
XXX.XXX
XXX.XXX
XXX
X.XX
X.XX
10 50.000
100.000
150.000
200
0.30
0.30
If the position data is set as above when the command is executed, 200 will be set in variable 100.