INTELLIGENT ACTUATOR

Part 1 Installation


Chapter 8 Maintenance

 Routine maintenance and inspection are necessary so that the system will operate properly at all

time. Be sure to turn off the power before performing maintenance or inspection.

 The standard inspection interval is six months to one year. If the environment warrants, however, the

interval should be shortened.


(1) Inspection points

 Check to see if the supply voltage to the controller is inside the specified range.

 Inspect the ventilation holes in the controller and remove dirt, dust and other foreign attachments, if

any.

 Inspect the controller cables (controller  actuator) and check for any loose screws or cable

disconnection.

 Check the controller mounting screws, etc., for looseness.

 Inspect each cable (axis link cable, general-purpose I/O cable, system I/O cable, power cable) for

loose connection, disconnection, play, etc.


(2) Spare consumable parts

Without spare parts, a failed controller cannot be repaired even when the problem is identified quickly.
We recommend that you keep the following consumable parts as spares:

Consumable parts

 Cables

 System-memory backup battery CR2032 (Note 1) --- 1 year (Note 2)

 Absolute-data backup battery by IAI IA-XAB-BT

--- 1 year (Note 2)

Condition of use

Temperature

40

C

Power supplied

0% of the time

Temperature

40

C

Power supplied

50% of the time

CR2032 (Note 1)

1.5 years

3 years

IA-XAB-BT by IAI

1 year

2 years

 Fuses

(Note 1) CR2032 refers to a battery conforming to the CR2032 standard, and any CR2032 battery

by any manufacturer can be used.

(Note 2) The actual battery life will vary depending on the use condition.

Memory backup
The X-SEL Controller saves program, position and parameter data to its flash memory (when written to
the flash memory). The data saved by the battery are positions, SEL global data and error lists. (Refer
to Chapter 1, “How to Save Data,” of Part 3.)

When the battery voltage drops, an applicable error code will be displayed on the panel window.

Error Codes Indicating Low Battery Voltage

System-memory backup battery

A01 or A02

Absolute-data backup battery

A03 or A23

In the case of a low battery voltage of the absolute-data backup battery, the axis-driver status LED will
also illuminate.