IAI America XSEL-KET User Manual
Page 168

149
Part 4 Commands
INTELLIGENT ACTUATOR
GDCL (Get deceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
GDCL
Variable
number
Position
number
CP
[Function] Obtain deceleration data from the deceleration item in the position data specified in operand
2, and set the value in the variable specified in operand 1.
[Example]
GDCL
100
10
Set the deceleration data at position No. 10 in variable 100.
Position No.
Axis 1
Axis 2
Axis 3
Vel
Acc
Dcl
1 XXX.XXX
XXX.XXX
XXX.XXX
XXX
X.XX
X.XX
2 XXX.XXX
XXX.XXX
XXX.XXX
XXX
X.XX
X.XX
10 50.000
100.000
150.000
200
0.30
0.30
If the position data is set as above when the command is executed, 0.3 will be set in variable 100.