Chapter 3 Operation

POWER CON

PCON-CA/CFA

86

3.2.4 Operation with the Position No. Input = Operations of PIO Patterns 0 to 3

This section describes the methods of operations of PIO patterns 0 to 3. These patterns

provide normal controller operation methods in which the controller is operated by turning the

start signal ON after a position No. is entered.

The control methods of positioning, pitch feed, and pressing are the same as those described

before.

[1] Positioning [Basic] (PC1 to PC**, CSTR, PM1 to PM**, PEND, MOVE, LOAD, TRQS)

Input

Output

PIO signal

PC1 to PC** CSTR PM1 to PM** PEND

MOVE LOAD TRQS

PIO pattern 0

PC1 to 32

{

PM1 to 32

{

{

u

u

PIO pattern 1

PC1 to 32

{

PM1 to 32

{

{

u

u

PIO pattern 2 PC1 to 128

{

PM1 to 128

{

u

u

u

PIO pattern 3 PC1 to 256

{

PM1 to 256

{

u

u

u

{

: Available, u: Unavailable

(Note) For incremental type, operation without home return leads the operation based on the

data of the specified position No. after automatic home return. If one or more problems

are found, interlock by home return complete signal HEND is required. Operation to the

specified position number would not take place under the condition that the home

position data is lost in the simple absolute type, but only the home-return operation will

be conducted.