Chapter 3 Operation

POWER CON

PCON-CA/CFA

64

(2) Pulse Train Control Mode

1) Set the pulse train format and the electric gear ratio (the distance of actuator movement in

mm against 1 pulse) to the parameters in the controller with using a teaching tool such as

PC software.

2) Send pulses based on the moving distance of the actuator to the controller from the PLC

(positioning unit).

3) The controller multiplies the entered number of pulses by the electrical gear ratio to get the

moving distance. The actuator is moved by the moving distance from the current position.

The velocity varies depending on the entered pulse rate (frequency).

4) After the positioning is completed, the completion signal is output.

The above procedure describes the basic operation method in the pulse train control mode.

Complete

Signal

Signal

Edit

Parameters of

controller

Actuator

Controller

Command

Pulse

PLC

Enter an electronic

gear ratio.

Teaching Tool