beautypg.com

Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 23

background image

POWER CON

PCON-CA/CFA

15

6) LED for Current/Alarm Monitoring

In the ordinary use, it shows the command current percentage and shows the alarm code

during an alarm being generated.

LED

Operation Status

STS3 (GN)

STS2 (GN)

STS1 (GN)

STS0 (GN)

Status Display

x

During servo-off: it displays the current command current ratio

(proportional to the rated current).

{

: Illuminating × : OFF

STATUS

3

2

1

0

Command Current Ratio

ALM8 ALM4 ALM2 ALM1

Simple alarm code

Ч

Ч

Ч

Ч

0.00% to 6.24%

Ч

Ч

Ч

{

6.25% to 24.99%

Ч

Ч

{

{

25.00% to 49.99%

×

{

{

{

50.00% to 74.99%

{

{

{

{

75.00% to 100.00% or more

x

During alarm generation: it displays the simple alarm code.

[Refer to 3.2.3 [7] and 3.3.2 [9] Binary Output of Alarm Data Output]

7) Axis Number Setting Switch

It is the switch to set the axis numbers when having an operation of multiple axes by the

serial communication, or when having the gateway operation.

Using the SIO converter allows multiple axes to be controlled on a teaching tool without

connection/disconnection of the connection cable connector. The SIO converter can specify

up to 16 axes with hexadecimal numbers 0 to F.

The setting of the switch is read at power-on of the controller. Changing the setting after the

power-on is invalid.

Caution : Note duplicate axis number setting, which causes a communication error

(alarm code 30C: no connection axis error) to occur and disables normal

communication.

8) Operation Mode Setting Switch (MANU/AUTO)

This switch is used for interlock so that a moving command from PIO (PLC) and a command

from the teaching tool may not be issued at a time.

AUTO… Allows auto operation by PIO signals. The teaching tool can only operate the

monitor.

MANU…Allows the teaching tool to operate the controller.

9) SIO Connector (SIO) [Refer to 2.3.5 SIO Connector Connection.]

The SIO connector is used to connect the controller with a teaching tool or a gateway unit

through a proper communication cable.

10) Motor • Encoder Connector [Refer to 2.1.3 [2] and 2.2.3 [2] Motor • Encoder Circuit]

It is the connector to connect the actuator motor and encoder cable.

Point the arrow at a desired

number with a flat-head

screwdriver