Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual
Page 182
Chapter 7 I/O Parameter
POWER CON
PCON-CA/CFA
174
[17] Zone 2+, Zone 2- (Parameter No.23, No.24)
[Refer to 7.2 [1].]
[18] PIO pattern selection (Parameter No.25)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
25 PIO pattern selection
IOPN
–
0 to 6
0 (Standard Type)
Select the PIO operation pattern in Parameter No.25.
For the details of PIO patterns, refer to 3.2 Operation in Positioner Mode and 3.3 Operation in
Pulse Train Control Mode.
Pattern type
Value set in
Parameter
No.25
Mode
Feature of PIO pattern
PIO
pattern 0
0
(factory
setting)
Positioning mode
(Standard type)
x
Number of positioning points: 64
x
Position command: Binary code
x
Zone signal output: 1 point
(Note)
x
Position zone signal output: 1 point
(Note)
PIO
pattern 1
1
Teaching mode
(Teaching type)
x
Number of positioning points: 64
x
Position command: Binary code
x
Position zone signal output: 1 point
(Note)
x
Jog operation enabled by PIO signal
x
Writing current position data to position table
enabled by PIO signal
PIO
pattern 2
2
256-point mode
(256-point type)
x
Number of positioning points: 256
x
Position command: Binary code
x
Position zone signal output: 1 point
(Note)
PIO
pattern 3
3
512-point mode
(512-point type)
x
Number of positioning points: 512
x
Position command: Binary code
x
Zone signal output: None
PIO
pattern 4
4
Solenoid valve
mode 1
(7-point type)
x
Number of positioning points: 7
x
Position command: Individual No. signal ON
x
Zone signal output: 1 point
(Note)
x
Position zone signal output: 1 point
(Note)
PIO
pattern 5
5
Solenoid valve
mode 2
(3-point type)
x
Number of positioning points: 3
x
Position command: Individual No. signal ON
x
Signal equivalent to LS (limit switch) enabled
x
Zone signal output: 1 point
(Note)
x
Position zone signal output: 1 point
(Note)
PIO
pattern 6
6
Pulse train
control mode
x
Differential pulse input (MAX.200Kpps)
x
Home return function
x
Zone signal output: 2 point
x
No feedback pulse output
(Note) Position Zone Signal can be switched over to Zone Signal. [Refer to Parameter No.149
Zone output changeover.]