beautypg.com

Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 216

background image

Chapter 8

Troubleshooting

POWER CON

PCON-CA/CFA

208

Alarm

Code Alarm Level

Alarm Name

Cause/Treatment

080

Move command in servo

OFF

Cause

: A move command was issued when the servo is

OFF.

Treatment : Issue a movement command after confirming the

servo is ON (servo ON signal (SV) or position

complete signal (PEND) is ON).

082

Position command in

incomplete home return

Cause

: A position move command was issued before

home return was completed.

Treatment : Issue a command after confirming that home

return has been completed (HEND) is ON.

083

Numerical command in

incomplete home return

Cause

: An absolute position command was issued by

numerical specification before home return was

completed (direct command from Field Network).

Treatment : Issue a numeric specification after performing

home return operation and confirming the

complete signal (HEND).

084

Absolute position move

command when home

return is not yet

completed

Cause

: A move command was issued when home return

was still in progress.

Treatment : Issue a movement command after performing

home return operation and confirming the

complete signal (HEND).

085

Position No. error during

movement

Cause

: A non-existing (invalid) position number was

specified in the positioner mode.

Treatment : Check the position table again and indicate an

effective position number.

086

Move command while

pulse train input is

effective

Cause

: Actuator operation was commanded via serial

communication in pulse train mode.

Treatment : Stop the actuator operation command via serial

communication in pulse train mode.

090

Software reset during

servo ON

Cause

: A software reset command was issued when the

servo was ON.

Treatment : Issue a software reset command after confirming

that the servo is OFF (SV signal is 0).

091

Position No. error in

teaching

Cause

: The position number out of the available range

was selected in the teaching.

Treatment : Select the position number from 63 or smaller.

092

PWRT signal detection

during movement

Cause

: The current position write signal (PWRT) was

input in the teaching mode of PIO pattern 1 while

the actuator was jogging.

Treatment : Input the PWRT signal after confirming that the

job button is not pressed and the actuator is

stopped (MOVE output signal is OFF).

093

Operation

release

PWRT signal detection in

incomplete home return

Cause

: The current position write signal (PWRT) was

input in the teaching mode of PIO pattern 1 when

home return was not yet completed.

Treatment : Input the HOME signal first to perform home

return, and then input the PWRT signal after

confirming that the home return has completed

(HEND output signal is ON).