Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

172

[10] Current-limiting value during home return (Parameter No.13)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

13 Current-limiting value during

home return

ODPW

%

1 to 100

In accordance

with actuator

The factory setting conforms to the standard specification of the actuator.

Increasing this setting will increase the home return torque.

Normally this parameter need not be changed. If the home return should be completed before

the correct position depending on the affixing method, load condition or other factors when the

actuator is used in a vertical application, the setting value must be increased. Please contact

IAI.

[11] Pause input disable (Parameter No.15)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

15 Pause input disable

FPIO

0 : Enabling

1 : Disabling

0

This parameter defines whether the pause input signal is disabled or enabled.

If pause from PIO is not required, setting the parameter to “1” allows the actuator to be

operated without wiring of the pause signal input.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)

[12] SIO communication speed (Parameter No.16)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

16 SIO communication speed

BRSL

bps

9600 to 230400

38400

Set the SIO baud rate for the startup.

Set an appropriate value in accordance with the communication speed of the host.

One of 9600, 14400, 19200, 28800, 38400, 76800, 115200 and 230400 bps can be selected as

the communication speed.

Caution: After the PC software is connected, the baud rate setting is changed to that of

the PC software. To make effective the value set in the parameter, cycle

controller power.

[13] Minimum delay time for slave transmitter activation (Parameter No.17)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

17 Minimum delay time for slave

transmitter activation

RTIM

msec

0 to 255

5

In this setting, set the time from receiving the command (received data) during the SIO

communication till the response (sent data) is returned to the host side.