Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual
Page 198
Chapter 7 I/O Parameter
POWER CON
PCON-CA/CFA
190
[73] IP address (Parameter No.140)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
140 IP address
IPAD
mm
0.0.0.0 to
255.255.255.255
192.168.0.1
It is the parameter dedicated for Field Network (EtherNet/IP).
[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]
[74] Subnet mask (Parameter No.141)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
141 Subnet mask
SNMK
–
0.0.0.0 to
255.255.255.255
255.255.255.0
It is the parameter dedicated for Field Network (EtherNet/IP).
[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]
[75] Default gateway (Parameter No.142)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
142 Default gateway
DFGW
–
0.0.0.0 to
255.255.255.255
0.0.0.0
It is the parameter dedicated for Field Network (EtherNet/IP).
[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]
[76] Overload level ratio (Parameter No.143)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
143 Overload level ratio
OLWL
%
50 to 100
100
Do not change the default value.
[77] Gain scheduling upper limit multiplying ratio (Parameter No.144)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
144 Gain scheduling upper limit
multiplying ratio
GSUL
%
0 to 1023
0(Disabling)
Gain scheduling is the function to change the gain in accordance with the operation speed.
This parameter shows the multiplying rate of the upper limit of the changeable gain.
With the set multiplying rate, the values for GS Velocity Loop Proportional Gain (Parameter
No.145) and GS Velocity Loop Integrated Gain (Parameter No.146) are changed.
Set Value
Description
100 or less
Gain scheduling disabled
101 to 1023 Gain scheduling enabled