Chapter 8
Troubleshooting
POWER CON
PCON-CA/CFA
216
Alarm
Code Alarm Level
Alarm Name
Cause/Treatment
0F5
Operation
release
Nonvolatile memory write
verify error
It is verified at the data writing process to the non-volatile
memory that the data inside the memory and the data to be
written are matched. There was a mismatch detected in this
process.
Cause
: Faulty nonvolatile memory.
Treatment : When the error is caused even when the power
is re-input, please contact IAI.
0F6
Nonvolatile memory write
timeout
There is no response in the specified time duration during the
data writing to the non-volatile memory.
Cause
: Faulty nonvolatile memory.
Treatment : When the error is caused even when the power
is re-input, please contact IAI.
0F8
Nonvolatile memory data
destroyed
Abnormal data was detected during the nonvolatile memory
check after starting.
Cause
: Faulty nonvolatile memory.
Treatment : When the error is caused even when the power
is re-input, please contact IAI.
0FA
CPU error
The CPU operation is not normal.
Cause
: 1) Faulty CPU.
2) Malfunction due to noise.
Treatment : When the error is caused even when the power
is re-input, please contact IAI.
0FC
Cold start
Logic error
(Faulty component)
The controller is not operating properly.
Cause
: 1) Malfunction due to the effect of noise, etc.
2) Malfunction of peripheral circuit components.
Treatment : Turn the power OFF and reboot.
If the error occurs again, check for presence of
noise.
If a spare controller is available, replace the
problem controller with the spare controller. A
recurring error with the spare controller suggests
presence of noise.
If the cause cannot be identified, please contact
IAI.
100 to
1FF
Message Alarm on teaching tool
[Refer to the Instruction Manual of teaching tool.]
200 to
2FF
Operation
release
Alarm on teaching tool
[Refer to the Instruction Manual of teaching tool.]
300 to
3FF
Cold start Alarm on teaching tool
[Refer to the Instruction Manual of teaching tool.]