4 alarm list, Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual
Page 215
Chapter 8
Troubleshooting
POWER CON
PCON-CA/CFA
207
8.4
Alarm List
Alarm
Code Alarm Level
Alarm Name
Cause/Treatment
02C
Monitoring data type
change command during
monitoring
Cause
: Changing data type was directed during
monitoring by the monitoring function of PC
software.
Treatment : Stop the monitoring before changing data type.
02D
Monitoring related
command in monitoring
function invalid status
Cause
: An attempt was made to perform monitoring in
the state where the monitoring function is set to
be ineffective.
Treatment : Set parameter No.112 (Selection of monitoring
mode) to “1” or “2” (“0”: no use).
02E
RTC related command in
RTC invalid status
Cause
: An attempt was made to use the calendar in the
state where the RTC (calendar) function was
made ineffective.
Treatment : Set parameter No.111 (Selection of use of
calendar function) to “1” (“0”: no use).
048
Driver overload alarm
Cause
: There is a risk of overload with the current
operation condition.
Treatment : Lower the setting of acceleration/deceleration.
Also, increase the frequency of pause.
04E
Exceeded movement
count threshold
Cause
: The total number of the operation times
exceeded the value set in Parameter No.147
“Total Movement Count Threshold”.
04F
Exceeded operated
distance threshold
Cause
: The total number of the operation distance
exceeded the value set in Parameter No.148
“Total Operated Distance Threshold”.
069
Detection of realtime
clock oscillation stop
Cause
: The calendar function is stopped and the current
time data is lost.
Treatment : Set the time again.
[Refer to the Instruction Manual of RC PC
software.]
(Note) This error is not registered in the alarm list.
06A
Realtime clock access
error
Cause
: The calendar function is not working properly
because of noise or malfunction of consisting
parts.
Treatment : 1) Take proper measures against noise.
2) When the calendar function is not used, set
parameter No.111 “Calendar function” to “0”.
3) If the operation is not improved in use of the
calendar function in spite of measures against
noise, Please contact IAI.
06B
Message
Maintenance information
data error
Cause
: The maintenance information (total movement
count, total operated distance) is lost.
Treatment : Please contact IAI.