Pcon-ca/cfa, Power con, Chapter 9 appendix – IAI America PCON-CA User Manual
Page 267
Chapter 9
Appendix
POWER CON
PCON-CA/CFA
259
Lead
Minimum
speed
Maximum speed
Maximum
acceleration/
deceleration
Minimum
push force
Maximum
push
force
Rated
push
speed
Actuator
series
Type
Feed
screw
No. of
encoder
pulses
[mm]
Mounting
direction
[mm/s]
[mm/s]
[G]
[N]
[N]
[mm/s]
Horizontal
(Note) It is the value
when
high-thrust
function is
effective.
1440 (at 50 to 500st)
1225 (at 550st)
1045 (at 600st)
900 (at 650st)
785 (at 700st)
690 (at 750st)
610 (at 800st)
1.0
20
Vertical
25
(Note) It is the value
when
high-thrust
function is
effective.
1280 (at 50 to 500st)
1225 (at 550st)
1045 (at 600st)
900 (at 650st)
785 (at 700st)
690 (at 750st)
610 (at 800st)
1.0
16
56
20
Horizontal
1.0
12
Vertical
15
(Note) It is the value
when
high-thrust
function is
effective.
900 (at 50 to 450st)
795 (at 500st)
665 (at 550st)
570 (at 600st)
490 (at 650st)
425 (at 700st)
375 (at 750st)
330(at 800st)
0.5
26
93
12
Horizontal
1.0
6
Vertical
7.5
(Note) It is the value
when
high-thrust
function is
effective.
450 (at 50 to 450st)
395 (at 500st)
335 (at 550st)
285 (at 600st)
245 (at 650st)
215 (at 700st)
185 (at 750st)
165 (at 800st)
0.5
53
185
6
Horizontal
1.0
RCP4
(slider
type)
SA5C
Ball
screw
800
3
Vertical
3.75
(Note) It is the value
when
high-thrust
function is
effective.
225 (at 50 to 450st)
195 (at 500st)
165 (at 550st)
140 (at 600st)
120 (at 650st)
105 (at 700st)
90 (at 750st)
80 (at 800st)
0.5
106
370
3