Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

180

[32] Operating-mode input disable (Parameter No.41)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

41 Operating-mode input disable

FPIO

0 : Enabling

1 : Disabling

0

This parameter defines whether the operation mode input signal is disabled or enabled.

Normally this parameter need not be changed.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)

[33] Enable function (Parameter No.42)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

42 Enable function

FPIO

0 : Enabling

1 : Disabling

1

Set valid/invalid the deadman switch function if the teaching pendant is equipped with a

deadman switch.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)

[34] Home position check sensor input polarit (Parameter No.43)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

43 Home position check sensor input

polarity

HMC

0: Sensor not used

1: a contact

2: b contact

0

Set the input signal polarity of the home position check sensor (option).

Since the home position check sensor is installed just below the mechanical end, if the actuator

reverses without reaching the mechanical end because of a reason such as interference, an

alarm will be generated because it will be identified as off the position and causes home

position sensor non-detected error.

It is generally unnecessary to change the setting.

Set Value

Description

0

Home position check sensor not used

1

Sensor polarity: Contact a

2

Sensor polarity: Contact b

[35] Silent interval magnification (ParameterNo.45)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

45 Silent interval magnification

SIVM

times

0 to 10

0

Use this parameter to set the silent interval (no communication) time by the time taken for

communication of 3.5 characters or longer before command data transmission when the

controller is operated via serial communication (RTU).

This parameter need not be changed when a teaching tool such as PC software is used.

If “0” is set, no multiplier is applied.