Absolute Reset and

Absolute Battery

POWER CON

PCON-CA/CFA

155

Chapter 6 Absolute Reset and Absolute Battery

6.1

Absolute Reset

The controller of simple absolute specification holds encoder position information by battery

backup. It is not necessary to perform the home-return operation every time the power is turned

ON.

In order to hold the encoder position information, absolute reset is required.

Provide absolute reset in the following cases:

(1) Initial activation

(2) When the absolute battery was replaced with the power to the controller is shut, and

(3) Disconnection of encoder cable from controller

The absolute reset is performed by using a teaching tool such as PC software or PIO. Each of

the absolute reset procedures is described below.

Caution: If it is Pulse Train Control Mode, it would not comply with simple

absolute type. Take the greatest care.

[1] Absolute reset procedure from teaching tool

1) Connect the controller with the actuator. [Refer to Chapters 1 and 2.]

2) Connect the absolute battery (Enclosed battery if starting up for the first time, new battery if

replacing) to the absolute battery connecting connector on the front panel of the controller.

[Refer to 6.2.]

3) Connect the teaching tool and turn ON the power of the controller.

4) The absolute encoder error appears on the teaching tool. Perform alarm reset.

5) Perform home-return operation. Once the home return is complete, the point of origin is

memorized at the same time the origin point is established.

In below explains the procedure using each teaching tool:

(1) For PC software

1) Select position data on the main screen and click the Alarm button.

Home Return

2) Select position data on the main screen and click the Home button.