Chapter 2 Wiring
POWER CON
PCON-CA/CFA
59
2.3.3 Connection of PIO
Conduct the connection of I/O to the controller is to be carried out using the dedicated I/O cable.
The cable length is shown in the model code of the controller. Please check the controller
model code. There are 2m for standard, 3m and 5m as an option. Up to 10m I/O cables are
sold separately. [Refer to 1.1.5 How to read the model]
Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut
and no treatment is conducted so the wiring layout can be performed freely.
Model : CB-PAC-PIOƑƑƑ
(ƑƑƑ indicates the cable length L. Example. 020 = 2m)
No.
Cable
Color
Wiring
No.
Cable
Color
Wiring
1A
BR-1
1B
BR-3
2A
RD-1
2B
RD-3
3A
OR-1
3B
OR-3
4A
YW-1
4B
YW-3
5A
GN-1
5B
GN-3
6A
BL-1
6B
BL-3
7A
PL-1
7B
PL-3
8A
GY-1
8B
GY-3
9A
WT-1
9B
WT-3
10A
BK-1
10B
BK-3
11A
BR-2
11B
BR-4
12A
RD-2
12B
RD-4
13A
OR-2
13B
OR-4
14A
YW-2
14B
YW-4
15A
GN-2
15B
GN-4
16A
BL-2
16B
BL-4
17A
PL-2
17B
PL-4
18A
GY-2
18B
GY-4
19A
WT-2
19B
WT-4
20A
BK-2
Flat Cable
٤
A
(Press Welding)
AWG28
20B
BK-4
Flat Cable
٤
B
(Press Welding)
AWG28
For the signal assignment of each wire, refer to the following considering the operation mode.
1) Positioner Mode······························2.1.3 [4] PIO Circuit
2) Pulse Train Control Mode···············2.2.3 [3] PIO Circuit