Chapter 8

Troubleshooting

POWER CON

PCON-CA/CFA

213

Alarm

Code Alarm Level

Alarm Name

Cause/Treatment

0D5

Cold start

Differential Counter

Overflow with Home

Return Incomplete

Cause

: This alarm indicates that the position deviation

counter has overflowed.

1) The speed dropped or stopped during JOG

move due to an impact of external force, hit to

the mechanical end or overload.

2) The excited-phase detection operation

following the power-on is unstable.

Treatment : 1) This error occurs when the actuator cannot be

operated as it is commanded. Check the load

conditions such as if the work is touching to

the surrounding object, or brake is properly

released, and remove the cause.

2) Overload is concerned. Revise the

transportable weight.

0D6

FAN error detection

Cause

: Error detected on heatsink fan inside the

controller

Treatment : If occurs, please contact IAI.

0D8

Deviation overflow

Cause

: This alarm indicates that the position deviation

counter has overflowed.

1) The speed dropped or the actuator stopped

due to the effect of external force or overload.

2) The excited-phase detection operation

following the power-on is unstable.

Treatment : 1) This error occurs when the actuator cannot be

operated as it is commanded. Check the load

conditions such as if the work is touching to

the surrounding object, or brake is properly

released, and remove the cause.

2) Overload can be concerned. Revise the

transportable weight and redo the

home-return operation.

0D9

Software stroke limit

exceeded

Cause

: The current position of the actuator exceeds the

software stroke limit.

Treatment : Return the actuator to be within the range of the

software stroke limit.

0DC

Operation

release

Pressing motion range

over error

Cause

: 1) After the pressing operation has complete,

the force to push back is too large and the

pushed back to the pressing start position

(“Position” in the position table).

2) The actuator touched the work during the

approach movement before the pressing

movement.

Treatment : 1) Revise the setting and adjust it so the force to

push back gets smaller.

2) Set the “Position” setting in front in the

position table to shorten the approach

distance.