Pcon-ca/cfa, Power con, 3 generation of noise and/or vibration – IAI America PCON-CA User Manual
Page 212
![background image](/manuals/350322/212/background.png)
Chapter 8
Troubleshooting
POWER CON
PCON-CA/CFA
204
8.2.3 Generation of noise and/or vibration
Situation
Possible cause
Check/Treatment
Generation of noise
and/or vibration from
actuator itself
Noise and vibration are generated by
many causes including the status of
load, the installation of the actuator, and
the rigidity of the unit on which the
actuator is installed.
Servo adjustment may improve the
situation.
[Refer to 7.3 Servo Adjustment.]
It may be improved with setting to
Full Servo Mode if the case occurs
during deceleration and stop.
[Refer to Chapter 5 Power-saving
Function]㩷
[In the case of Positioner Mode]
Situation
Possible cause
Check/Treatment
Vibrations of load
1) Acceleration/deceleration is set too
high.
2) The installation structure and/or the
installed load are easily affected by
acceleration/deceleration.
1) Decrease the settings of
acceleration/deceleration.
[In the case of Pulse Train Control Mode]
Situation
Possible cause
Check/Treatment
Vibrations of actuator or
load
Acceleration/deceleration is set too
high.
Decrease the setting of
acceleration/deceleration in the
host controller.
Generation of noise
during acceleration
The host controller has no
acceleration/deceleration function or
does not have acceleration/deceleration
function from speed 0.
(Some positioning units have
acceleration/deceleration function but
cannot use the function from speed 0.
Note this when you select a positioning
unit.)
[Refer to 7.3 Servo Adjustment
No.7]