4 Networking Switch Modules
468
Static RP
Parameter
Description
Group Threshold
This parameter is a bits-per-second (BPS) value that
when it exceeds a certain value, initiates source specific
counters for a particular group.
Source Threshold
This parameter is a bits-per-second (BPS) value that
when exceeds a certain value, initiates switching to
shortest path tree.
Switching Period
This parameter specifies the time interval that the data
rate is monitored for, initiating the counters or for
switching to SPT.
RP Threshold
When the number of registered packets received
exceeds this threshold value, RP initiates switching to
SPT.
RP Switching
Period
This parameter specifies the time interval for which the
registered packets are monitored to initiate switching