beautypg.com

Rainbow Electronics W90N745CDG User Manual

Page 402

background image

W90N745CD/W90N745CDG

- 398 -

SYMBOL DESCRIPTION MIN.

MAX.

UNIT

T1

Time from DATA transition to falling edge of CLK

5

25

us

T2

Time form rising edge of CLK to DATA transition

5

T4-5

us

T3

Duration of CLK inactive

30

50

us

T4

Duration of clock active

30

50

us

T5

Time to auxiliary device inhibit after clock 11 to ensure the
auxiliary device does not start another transmission

0 50 us

T7

Duration of CLK inactive

30

50

us

T8

Duration of CLK active

30

50

us

T9

Time to fom inactive to active CLK transition, used to time
when the auxiliary device samples DATA

30 50 us