Rainbow Electronics W90N745CDG User Manual
Page 399
W90N745CD/W90N745CDG
Publication Release Date: September 22, 2006
-
395
-
Revision
A2
7.3.6 I
2
C Interface AC Characteristics
T
SU:STO
T
SU:DAT2
T
LOW
T
HIGH
T
hd:DAT
T
SU:DAT
T
hd:STA
SCL
SDA
SCL
SDA
T
SU:SAT
SYMBOL DESCRIPTION MIN
MAX
UNIT
T
HIGH
I
2
C Clock high time
1
-
us
T
LOW
I
2
C clock low time
1
-
us
T
hd:STA
Start condition hold time
1
-
us
Receive data setup time
0.1
-
us
T
SU:DAT
Transmit data output delay
-
0.5
us
Receive data hold time
1
-
us
T
HD:DAT
Transmit data hold time
0
0.9
us
T
SU:DAT2
SDA setup time (before STOP condition)
0.5
-
us
T
SU:STO
Stop condition setup time
1
-
us
T
SU:STA
Restart condition setup time
1.5
-
us
See also other documents in the category Rainbow Electronics Sensors:
- MAX5151 (16 pages)
- MAXQ3108 (64 pages)
- MAX5661 (39 pages)
- MAX6691 (7 pages)
- MAX5362 (12 pages)
- ADC10158 (26 pages)
- MAX8922L (14 pages)
- MAX8596Z (8 pages)
- MAX7491 (18 pages)
- MAX15040 (15 pages)
- MAX5177 (16 pages)
- ADC08138 (22 pages)
- MAX5961 (42 pages)
- T89C51RD2 (86 pages)
- MAX16055 (9 pages)
- MAX6659 (17 pages)
- ADC0820 (20 pages)
- MAX6678 (19 pages)
- MAX8884Z (15 pages)
- MAX16915 (9 pages)
- MAX8620 (18 pages)
- MAX5144 (12 pages)
- MAX6670 (8 pages)
- MAX8760 (39 pages)
- W78C32C (14 pages)
- MX7533 (8 pages)
- MAX8727 (13 pages)
- MAX9053 (15 pages)
- W78C54 (16 pages)
- MAX8614B (15 pages)
- W90N740 (219 pages)
- MAX6626 (13 pages)
- ADC10738 (30 pages)
- MAX17000 (31 pages)
- MAX5051 (21 pages)
- MAXQ1004 (18 pages)
- MAX6871 (51 pages)
- MX7847 (12 pages)
- MAX6608 (6 pages)
- MAX17083 (15 pages)
- MAX6641 (17 pages)
- MAX5251 (16 pages)
- MAX6338 (8 pages)
- MAX6690 (16 pages)
- MAX8668 (18 pages)