background image

W90N745CD/W90N745CDG

- 362 -

PWM Prescaler Register (PWM_PPR)

REGISTER ADDRESS R/W

DESCRIPTION

RESET

VALUE

PWM_PPR

0xFFF8_7000

R/W PWM Prescaler Register

0x0000_0000

31

30

29

28

27

26

25

24

DZI1

23

22

21

20

19

18

17

16

DZI0

15

14

13

12

11

10

9

8

CP1

7

6

5

4

3

2

1

0

CP0

BITS

DESCRIPTIONS

[31:24]

DZI1

DZI1: Dead zone interval register 1, these 8-bit determine dead zone

length.
The 1 unit time of dead zone length is received from clock selector 2.

[23:16]

DZI0

DZI0: Dead zone interval register 0, these 8-bit determine dead zone
length.
The 1 unit time of dead zone length is received from clock selector 0.

[15:8]

CP1

CP1 : Clock prescaler 1 for PWM Timer channel 2 & 3
Clock input is divided by (CP1 + 1) before it is fed to the counter. 2 & 3
If CP1=0, then the prescaler 1 output clock will be stopped.

[7:0]

CP0

CP0 : Clock prescaler 0 for PWM Timer channel 0 & 1
Clock input is divided by (CP0 + 1) before it is fed to the counter. 0 & 1
If CP0=0, then the prescaler 0 output clock will be stopped.