beautypg.com

Star Micronics Line Thermal/Dot Printer User Manual

Page 71

background image

Rev. 0.00

3-59

STAR Line Mode Command Specifications

• n3: Bar Code Mode Selection

n3

Bar Codes Types

UPC-E, UPC-A, JAN/EAN8

Code39, NW-7

ITF

JAN/EAN13, Code128, Code93

1, 49

Minimum module 2 dots

Narrow : Wide = 2: 6 dots

Narrow : Wide = 2: 5 dots

2, 50

Minimum module 3 dots

Narrow : Wide = 3: 9 dots

Narrow : Wide = 4:10 dots

3, 51

Minimum module 4 dots

Narrow : Wide = 4:12 dots

Narrow : Wide = 6:15 dots

4, 52

---

Narrow : Wide = 2: 5 dots

Narrow : Wide = 2: 4 dots

5, 53

---

Narrow : Wide = 3: 8 dots

Narrow : Wide = 4: 8 dots

6, 54

---

Narrow : Wide = 4:10 dots

Narrow : Wide = 6:12 dots

7, 55

---

Narrow : Wide = 2: 4 dots

Narrow : Wide = 2: 6 dots

8, 56

---

Narrow : Wide = 3: 6 dots

Narrow : Wide = 3: 9 dots

9, 57

---

Narrow : Wide = 4: 8 dots

Narrow : Wide = 4:12 dots

• n4: Bar code height (dot count)

Spec. 1: When the height of the bar code is more than the form feed amount, the form feed amount

is automatically doubled.

Spec. 2: Line feed according to (bar code height + under-bar characters)

• k (bar code data count), d (bar code data)

Bar Codes Types

Defined area of k

Defined area of d

UPC-E

11 ≤ k ≤ 12

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”)

UPC-A

11 ≤ k ≤ 12

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”)

JAN/EAN8

7 ≤ k ≤ 8

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”)

JAN/EAN13

12 ≤ k ≤ 13

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”)

Code39

1 ≤ k

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”), 65 ≤ d ≤ 90 (“A” ≤ d ≤ “Z”)
32, 36, 37, 43, 45, 46, 47(SP, “$”, “%”, “+”, “-”, “.”, “/”)

ITF

1 ≤ k
For odd numbers
0 data is automatically added

to the top.

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”)

Code128

1 ≤ k

0 ≤ d ≤ 127

Code93

1 ≤ k

0 ≤ d ≤ 127

NW-7

1 ≤ k

48 ≤ d ≤ 57 (“0” ≤ d ≤ “9”), 65 ≤ d ≤ 68 (“A” ≤ d ≤ “D”)
36, 43, 45, 46, 47, 58 (“$”, “+”, “-”, “.”, “/”, “:”)
97, 98, 99, 100 (“a,” “b,” “c,” “d”)

• UPC-E: k = 11 (or 12)

The 12

th

check digit is automatically applied, so it is ignored even if specified.

Command is ignored if the data cannot be shortened. Data conversion to rectangles is automatic.

• UPC-A: k = 11 (or 12)

The 12

th

check digit is automatically applied, so it is ignored even if specified.

• JAN/EAN -8: k = 7 (or 8)

The 8

th

check digit is automatically applied, so it is ignored even if specified.

• JAN/EAN -13: k = 12 (or 13)

The 13

th

check digit cannot be automatically applied, so it is ignored even if specified.

• CODE39: k is freely set, and maximum value differs according to the mode.

Start and stop codes (*) are automatically included.

• ITF: k is freely set, and maximum value differs according to the mode.

If the data is an odd line, 0 data is automatically appended to the top.

• CODE128: k is freely set, and maximum value differs according to the mode and print character

type.

Check character is automatically appended.

• CODE93: k is freely set, and maximum value differs according to the mode and print character

type.

The start/stop code (□) is automatically appended.

• NW7: k is freely set, and maximum value differs according to the mode and print character type.

Both start/stop codes are included in the data (but not automatically applied).