5-9
STAR LIne Mode Command Specifications
(3)
Printer Status
Printer status is the status of the printer sent from the 3
rd
byte of the automatic status.
For the printer status, (the number of bytes added in Header -1 minus two) is returned.
Printer status is always updated for new information. (No log exists.)
The following shows the composition of the status.
Bit
Contents
Status
By model
“0”
“1”
HSP7000
7
Fixed at “0”
-
-
6
OFFLINE By Switch Input
No
Occurs
×
5
Cover Status
Closed
Open
○
4
Fixed at “0”
-
-
3
ONLINE/OFFLINE Status
ONLINE
OFFLINE
○
2
Compulsion SW
Open
Closed
○
1
ETB Command
Not Executed
Executed
○
0
Fixed at “0”
-
-
• ETB Command
Cleared when received at the host (by clearing bit 1 to 0, automatic status is not targeted to occur).
Bit
Contents
Status
By model
“0”
“1”
HSP7000
7
Fixed at “0”
-
-
6
Stopped by high head
temperature
Not stopped
Stopped
○
5
Non-recoverable Error
No
Yes
○
4
Fixed at “0”
-
-
3
Auto-cutter Error
No
Yes
○
2
Mechanical Error
No
Yes
○
1
Not Used (Fixed at “0”)
-
0
Fixed at “0”
-
-
Bit
Contents
Status
By model
“0”
“1”
HSP7000
7
Fixed at “0”
-
-
6
Reception Buffer Overflow
Does not occur
Occurs
○
5
Command Error (in Page
Mode)
No
Yes
x
4
Fixed at “0”
-
-
3
BM Error
No
Yes
○
2
Presenter Paper Jam Error
No
Yes
×
1
Head Up Error
No
Yes
×
0
Fixed at “0”
-
-
• Reception Buffer Overflow
Cleared to 0 when returned to the host.
• Command Error (in Page Mode)
Command errors cleared to 0 when returned to the host.
• BM Error
On models that use a common PE and BM sensor, if a continuous error is detected beyond a determined amount, it
indicates not a black mark error, but a paper out error.